Product List


Open Matrix System(OMS)


Data & Fiber Optic Cables


Connecting Hardware


Real Time Patching System


Cabling Solutions


Fire Performance Standard
 
E-shop
FAQ
Download
Contact
 
 
HomeProduct DispalyNavigation 
Product Profile  
<
                         
   
Product name: Tight Buffer Distribution Fiber Optic Cables
         
Keywords:
Indoor Fiber Optic Cables,Tight Buffer Distribution Fiber Optic Cables
                                   
    Product Picture      
   
     
                 
Product Introduction
Tight Buffer Distribution Fiber Optic Cables

◎ Applications:
Short and medium distance, indoor and protected environments. Offered as a riser, plenum, or general purpose cable,
it is used for interconnection of distribution boxes, or the distribution boxes and customer equipments, and between
floors.

◎ Installations:
Installed along the wall, the roof, interlayer, canal and indoor.

◎ Construction:
The cable contains 4 to 72 fibers individually buffered to 0.9 mm in a tight or semi tight construction and coded. The
cable structure depends on the number of fibers: The 4 to 12 fiber cables contain individual fibers without sub-units,In
the 16 to 72 fiber cables the fibers are grouped in the sub-units. In the 4 to 12 fiber cables, the individual fibers are
stranded and protected by aramid yarn and a PVC or LSZH jacket. In the 16 to 72 fiber cables, the fibers are grouped
into sub-units which are laid helically along the cable axis. Each sub-unit contains 4 to 6 fibers, aramid yarn and a
PVC or LSZH jacket. The 72 fiber cable consists of twelve sub-units, nine of them are stranded around a central
element made of 3 sub-units.

◎Technical Parameters:
☆ Maximum Transmission Distance: 6km (Single Mode); 0.3km (Multimode)
☆ Maximum Pulling Load: 100N(Short Term Installation);60N(Long Term Install) ☆
Minimum Bending Radius:
Short Term Installation: 20 x Overall Diameter
Long Term Installation: 10 x Overall Diameter (Non-Armoured);
20 x Overall Diameter (Armoured)
☆ Twist (Torsion Length): 125 x Overall Diameter.
☆ Working Temperature: -10℃ ~ +70℃ (PE sheath)
☆ Storage Temperature: -20℃ ~ +70℃ (PE sheath)

◎ Product Highlights:
☆ Small diameter and light weight.
☆ The high tension characteristics of the aramid yarn serving as strength member
can offer good stability in the transmission performance.
☆ Compact and flexible construction are especially suitable for indoor installations.
☆ Tight Buffer fibers are made from fiber rods with good linearity and low extruding output. By careful calibration of
the vacuum pumping equipment, the uniformity of the outer diameter of the tight buffer fibers can be easily achieved
with excellent strip ability.
☆ LSZH jackets can be offered for indoor application for which flame retardancy is required.
☆ Cutting edge production equipment, good quality materials and optimized process ensure low induced attenuation
within the operating temperature range.
☆ Fiber geometry are strictly monitored to ensure superior transmission performance.

◎ Ordering Information:
AD-MTA-B-C-D-E-F-G-H-I-J-K-L
A: Small Unit Diameter
A=0.9mm (12 core);
B=3.6mm (12-16 core);
C=4.2mm (24-72 core)
B: Fiber Types
0=Fibers and copper conductors in cable; 1=Two or more fiber types in a cable
4=50/125 Multimode (OM3); 5=50/125 Multimode (OM2)
6=62.5/125 Multimode (OM1); 7= NZDS SM fiber per G.656
8=NZDS SM fiber per G.655; 9=Standard SM fiber per G.652D
C: No of Fibers per Tubes: 4-72
D: Subunit Jacket Material
Y=PVC; H=LSZH
11Y=PU; 0=No subunit (0-12 core fiber)

E: Central Member
A=Aramid yarn; F=Dielectric (FRP)
F: Inner Jacket Options
2Y=PE; Y=PVC; H=LSZH
G: Armour Options
Blank=No armour; T=Corrugated steel tape armour; W=Steel wire armour
B=Bronze armour; D=Fiber glass armour; TW= Steel tape + Steel wire armour
H: Jacket Material Options
2Y=PE; Y=PVC; H=LSZH
11Y=PU; A=Aluminium moisture barrier; T=Anti-termite protection
I: Water-blocking Options for Cable Cores
X= No water-blocking; J=Cable core gel in tubes; D=Dry water-blocking in cable core interstices
J: Water-blocking Options for Cables with more than one Jacket
X=No Water-blocking; J= Water-blocking gel between jackets; D=Dry water-blocking between cable jackets
K: Tight Buffer Types
VT=Standard TB; YT=Tactical level
CG=Jelly filled, Semi tight buffered; CD=Dry, Semi tight buffered
L: Strength member options
A=Aramid yarn; AG=Aramid yarn and fiber glass yarn; G=Fiber glass yarn